SmartRow Cruizer Interface and Calibration
SmartRow Modes
The available modes for operating SmartRow are:
Standard SmartRow Job
SmartRow Job with No Plant Zone
SmartRow Job with Field Boundary
SmartRow Job with Field Boundary and No Plant Zone
Standard SmartRow Job
As sections enter previously painted areas, SmartRow automatically turns that section OFF. When the
section leaves the previously painted area, SmartRow automatically turns the section back ON.
The standard field boundary tools are used while operating in Standard SmartRow Mode.
No Plant Zone Mapping Mode
No Plant zones may be created and around any areas in which product application should be avoided,
such as waterways or around well heads.
For example, as the vehicle crosses into a no plant zone, SmartRow automatically shuts off any
section that enters the no plant zone while other sections remain enabled. As the sections reenter un-
painted zones, SmartRow automatically toggles product application back on.
Field Boundaries
Field Boundaries within a SmartRow enabled Job automatically create a zone map based upon the
completed boundary.
SmartRow assigns a minimum of three implement widths outside of the completed field boundary of a
plant zone.