Look Ahead
SmartBoom allows you to pre-program Turn-On and Turn-Off Look Ahead times. SmartBoom monitors
the GPS position and as-applied map while considering the Look Ahead times to begin turning booms
on or off before they cross spray or no spray boundaries. Look Ahead times can help compensate for
delays in the sprayer system including the time it takes for boom valves to open and close. The
specific Look Ahead time is a function of the valve timing and the speed at which the operator is driving
the machine.
Percent Coverage
SmartBoom provides the ability to pre-define the amount of coverage SmartBoom will apply. For most
applications that require complete coverage, the Percent Coverage should be set to 100 percent. For
applications that will not tolerate overlap, the Percent Coverage should be set to a lower value.
SmartBoom allows a Percent Coverage value anywhere from 5 to 100 percent in increments of 5
percent.
SmartBoom Override
SmartBoom provides you the ability to momentarily override the SmartBoom feature and force all
boom sections on. This may be desired if you want to double up coverage on an area of the field. The
override feature is also used when starting off from a dead stop. Enable the SmartBoom Override
feature and allow the boom valves to open up before driving ahead. The amount of time for the
override can be modified to match your specific application needs.
Manual Control
SmartBoom provides you with the ability to manually toggle individual boom sections on or off. Manual
Control is useful in situations when parts of a boom section will overlap other crop areas.