Raven Cruizer II Operator's Manual Page 30

  • Download
  • Add to my manuals
  • Print
  • Page
    / 98
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 29
Chapter 6
24 SmartBoom and SmartRow Installation and Operation Manual
6. Configure the Implement Locations - If this is a standard configuration, use the SmartRow
Autoloaded feature to configure the location of each section with respect to the GPS antenna. If a
custom configuration is used, use the optional boom configuration screens to set the location of
each boom section with respect to the GPS Antenna.
FIGURE 1. Section Location Example
7. Set the Look Ahead Times - Use the SmartRow Configuration menus to set the Turn On and Turn
Off Look Ahead Times. The default setting is 0.1 seconds.
8. Set the Override Time - Use the SmartRow Configuration menus to set the Override Time. The
default setting is 5 seconds.
9. Set the Percent Coverage - Use the SmartRow Configuration menus to set the Percentage
Coverage. The default setting is 100 percent.
10. Select The Booms To Be Controlled - Use the SmartRow Configuration menus to select which
booms will be controlled by SmartRow. The default setting allows SmartRow to control all boom
sections.
About SmartRow Jobs
SmartRow provides several methods of operation. These include:
Standard Job
Job with field boundary
Job with no plant zones
Job with field boundary and no plant zones
2 3
Section 1
GPS Antenna
Fore/Aft
Left/Right
Section
Section
Page view 29